How to Fix MySQL Error 3055 (ER_GIS_DATA_WRONG_ENDIANESS)

Published
Length
3 min read

Luis Felipe Dias

All posts

You get mysql error 3055 when the server receives spatial geometry data in big endian format. You fix it by converting your geometry byte strings to little endian before you write them. MySQL logs this problem with the symbol ER_GIS_DATA_WRONG_ENDIANESS and the state HY000. The server message states that the geometry byte string must be little endian. When a client sends the wrong byte order, the database stops the write right away. This check keeps bad map data out of your tables. Why mysql

Your coding agents run with your access.

Claude Code reaches prod with a developer's credentials, and approval prompts get clicked through. hoop.dev checks every query, masks sensitive data, and holds risky changes for a human.

You get mysql error 3055 when the server receives spatial geometry data in big endian format. You fix it by converting your geometry byte strings to little endian before you write them.

MySQL logs this problem with the symbol ER_GIS_DATA_WRONG_ENDIANESS and the state HY000. The server message states that the geometry byte string must be little endian. When a client sends the wrong byte order, the database stops the write right away. This check keeps bad map data out of your tables.

Why mysql error 3055 happens in spatial queries

MySQL stores spatial values using an internal geometry format based on standard binary rules. The first part of this binary payload contains a spatial reference number and a byte order mark. For internal storage, MySQL requires that byte order mark to signal little endian format. If the byte mark signals big endian, the engine raises mysql error 3055.

This issue often starts when an app builds binary geometry values in memory on its own. Some external map tools and older servers default to big endian byte order when exporting data. If your app passes raw bytes straight to an insert query, the storage engine rejects them. It also happens when teams move raw binary dumps between different database systems without converting them.

Another cause is using the wrong spatial import method in your query. Standard binary geometry payloads can use either byte order when you pass them to conversion routines. Still, raw internal geometry writes demand little endian byte strings every single time. Mixing up standard binary payloads and internal MySQL geometry payloads will trigger this failure.

How to diagnose and fix the byte order safely

Start by checking the app logs to find which query triggered the spatial failure. Look at how the client prepares the geometry payload before sending it to the database. Check the first byte after the spatial reference header in your raw binary input. In standard binary geometry, a value of one marks little endian while zero marks big endian.

MySQL Access Governance + End-to-End Encryption: architecture patterns and best practices

Continue reading? Get the full guide.

Free. No spam. Unsubscribe anytime.

You should never bypass validation or grant wide admin rights to force raw byte writes. Instead, update your data pipeline to pass standard binary data through MySQL spatial import routines. Those built-in spatial routines read big endian inputs and swap the bytes to little endian. If your app writes raw bytes, set up your code library to output little endian values.

How to prevent spatial byte order failures in production

Teams can stop this error early by checking binary map inputs at the app layer. Set up unit tests that verify the byte order mark before any database write runs. When you pull map data from outside partners, run a conversion step in your staging pipeline. This step turns all incoming map shapes into a single standard format.

You should also restrict who can run ad hoc spatial imports on live tables. Give developers scoped roles so they test data loads in a safe test space first. When engineers inspect live spatial rows, mask sensitive columns like emails or phone numbers in results. Good query logs and clear role rules help teams spot bad spatial writes fast.

Check MySQL queries and results on the wire

MySQL grants control who logs in. They do not check single queries or mask sensitive columns once a session starts. With hoop.dev, you run an open-source proxy, a sidecar for your MySQL, inline in the MySQL wire protocol. On every query an AI agent or human runs against production MySQL, RDS, or Aurora, hoop.dev decides to pass, mask, block, or hold it for review.

Multi-statement batches and prepared queries are split and checked one by one by hoop.dev guardrails, which refuse banned queries with a native MySQL error or hold risky ones for approval. On the response path, hoop.dev data masking rewrites string values in returned rows in memory, and every decision is logged. See the MIT-licensed project on GitHub.

Frequently asked questions

What does ER_GIS_DATA_WRONG_ENDIANESS mean in MySQL?

It means the database received a geometry byte string that does not use little endian order. MySQL uses code 3055 and state HY000 to block the bad spatial value.

Can MySQL read big endian geometry data at all?

Yes, standard spatial import routines can read big endian binary shapes and convert them for you. The error happens when a query tries to use big endian bytes as internal storage values.

Does fixing mysql error 3055 require a database restart?

No, you do not need to restart the server or change any system settings. You only need to fix the byte order in your query or app data pipeline.

The query runs. The emails stay hidden.