How to Fix SQL Server Error 41350 (Msg 41350)
You see sql server error 41350 when you create a durable memory optimized table inside an encrypted database. You fix it by changing table durability or adjusting database encryption settings to match your security policy. This message has a severity level of ten. That means the database engine treats it as an informational warning rather than a hard failure. Your table creation command still finishes, and your app can still read and write rows. What causes sql server error 41350 in your data
Your coding agents run with your access.
Claude Code reaches prod with a developer's credentials, and approval prompts get clicked through. hoop.dev checks every query, masks sensitive data, and holds risky changes for a human.
You see sql server error 41350 when you create a durable memory optimized table inside an encrypted database. You fix it by changing table durability or adjusting database encryption settings to match your security policy.
This message has a severity level of ten. That means the database engine treats it as an informational warning rather than a hard failure. Your table creation command still finishes, and your app can still read and write rows.
What causes sql server error 41350 in your database
The database engine raises message 41350 during table creation. It happens when a memory optimized table uses schema and data durability inside an encrypted database. The official message warns that the new table sits in a database enabled for encryption.
Memory optimized tables keep data in main memory for fast access. When you pick schema and data durability, the engine also writes changes to disk. This lets the database keep your rows if the server restarts.
Database encryption protects data files on disk. Still, memory optimized filegroups handle storage and recovery differently than standard disk tables. The engine logs message 41350 so admins check how encryption rules apply to those memory structures and disk checkpoint files.
Because severity ten is an informational warning, automated deployment scripts might still flag it. Strict release pipelines often treat any unexpected engine message as a build failure. Knowing why the message appears helps your team decide the right fix.
How to check and fix the warning in production
Start by checking whether the table needs to keep data after a restart. Some memory optimized tables only hold temporary cache data or staging rows. If the app can rebuild the data, change the table to schema only durability.
Tables with schema only durability do not write data rows to disk. When you use schema only durability, the engine does not raise message 41350. Your table design stays intact, and all data fades when the server restarts.
If your business rules require durable data and encryption at rest, review your storage setup. Check your database encryption state and confirm how checkpoint files are stored on disk. Make sure your disk security meets your internal compliance goals before ignoring the warning.
Kubernetes API Server Access + End-to-End Encryption: architecture patterns and best practices
Continue reading? Get the full guide.
Free. No spam. Unsubscribe anytime.
When you check production databases, do not grant broad rights to your team. Avoid adding engineers to the fixed owner role just to inspect table settings. Members of the owner role can change any setting or even drop the database.
Instead, map each person to a dedicated login and database user. For someone who checks many databases on one instance, use a login in master. For access to one or a few databases, you can use a contained database user.
Keep permissions tight during diagnosis. The fixed data reader role lets users read all data from user tables and views. It does not let them change schemas or drop objects, which keeps production safe.
How to prevent deployment script failures from message 41350
Release tools often parse database output logs during schema updates. When a script creates a durable memory optimized table, message 41350 appears in the output. If your deployment tool stops on every warning, your release will stall.
Update your deployment checks to tell severity ten warnings apart from real errors. Real failures in the database engine use higher severity numbers. Teaching your release runner to allow message 41350 keeps safe schema updates moving.
You should also test schema changes in a staging database that matches production. If production uses database encryption, enable encryption in staging too. This helps your team spot message 41350 early before the code reaches live servers.
Also review who can run schema changes in production. Fixed roles have set permissions that you cannot change. Give write or schema rights only to the automated release role, and keep human users on read roles.
Add runtime guardrails beside SQL Server
Role grants and network rules are needed setup for SQL Server. Still, an allowed user or agent tool can send a bad delete or read raw customer fields over a valid session. In practice, hoop.dev sits inline in the TDS protocol beside the database as a sidecar for your SQL Server. For every query an agent or human runs in production, hoop.dev decides whether to pass, mask, block, or escalate it for review.
With hoop.dev SQL Server controls, rules refuse banned statements before they run, hold risky queries for human review, and mask matched sensitive values in supported result columns in memory. Furthermore, hoop.dev holds SOC 2 Type II and generates evidence for HIPAA, PCI DSS, SOX, and GDPR audits. See the source on GitHub.
Frequently asked questions
Does sql server error 41350 stop my table from being created?
No, message 41350 has a severity level of ten, which is just a warning. The database engine finishes creating your memory optimized table and lets queries run normally.
When does the database engine trigger message 41350?
The engine triggers this warning when you create a memory optimized table with schema and data durability. It only happens when the target database is enabled for encryption.
What database role should engineers use to check table data safely?
Assign engineers to the fixed data reader role so they can read user tables and views. Never use the database owner role for routine checks, because it can drop the database.
Related guides
In this post