How to Fix MySQL Error 4003 (ER_DA_ERROR_LOG_MULTIPLE_FILTERS)
You see mysql error 4003 when the global error log service list has multiple filters. You can fix it by keeping only one log filter service in the list. MySQL maps this issue to symbol ER_DA_ERROR_LOG_MULTIPLE_FILTERS and SQLSTATE HY000 in its system logs. The database warns that multiple filters make log output very hard to read. When two filters run at once, one filter can hide events from the next. Your team might miss critical alerts during a database outage because of this clash. Root ca
Your coding agents run with your access.
Claude Code reaches prod with a developer's credentials, and approval prompts get clicked through. hoop.dev checks every query, masks sensitive data, and holds risky changes for a human.
You see mysql error 4003 when the global error log service list has multiple filters. You can fix it by keeping only one log filter service in the list.
MySQL maps this issue to symbol ER_DA_ERROR_LOG_MULTIPLE_FILTERS and SQLSTATE HY000 in its system logs. The database warns that multiple filters make log output very hard to read. When two filters run at once, one filter can hide events from the next. Your team might miss critical alerts during a database outage because of this clash.
Root causes of mysql error 4003 in the database engine
The MySQL error log pipeline processes system events through a chain of built-in components. These components fall into two main groups: log filters and log sinks. A filter decides which events stay and which events get dropped or changed. A sink writes the final log message to a file, system log, or table.
The engine triggers mysql error 4003 when the global log service string includes two filters. Database admins often cause this by adding a new filter without removing the old one. For example, a team might add a rule-based filter while the priority filter still runs. Automated startup scripts can also append extra filter names during a server upgrade. While the server may still run, the warning shows that your log setup is unsafe.
How to check your error log service chain
Start by reading the current global error log service value on the affected server. Check the order of the components listed in that system value. Look for more than one component that acts as an event filter. You can have multiple output sinks, such as a text file and a JSON writer. Still, you should only run a single filter before those output sinks.
Review your server startup files as well to see where the value gets set. Look for extra files included by your main database startup file. Sometimes a cloud template sets one filter while a custom file adds another. Finding both sources stops the problem from coming back after the next server reboot.
MySQL Access Governance + End-to-End Encryption: architecture patterns and best practices
Continue reading? Get the full guide.
Free. No spam. Unsubscribe anytime.
How to fix the error safely in production
To clear the warning, pick the single log filter that fits your team needs. Update the global error log service list so it holds only that one filter. Place the chosen filter first in the list, followed by your desired log sinks. Apply the change in a test setup first to check the resulting log output.
Do not grant broad superuser rights to everyday users just to fix log settings. Keep system variable changes restricted to senior database admins or approved update pipelines. After updating the live server, save the same clean list in your startup file. This step ensures the database starts cleanly the next time it restarts.
Inspect every MySQL query and response in flight
Static grants and network rules block bad logins. They cannot pause a risky query for review or mask emails in a result set. By design, hoop.dev sits inline in the MySQL protocol as a sidecar for your MySQL. For every plain query, prepared statement, or cursor an agent or human runs in production, hoop.dev decides to pass, mask, block, or hold it for review.
First, hoop.dev guardrails block banned actions before MySQL runs them, and an AI Analyzer you configure can score intent or escalate for approval. Next, hoop.dev data masking rewrites sensitive string columns in results in memory, and every verdict goes to the audit trail. Find the open-source binary on GitHub.
Frequently asked questions
Does mysql error 4003 stop the database from running?
No, this message acts as a warning rather than a fatal crash error. Still, leaving multiple filters active can hide important database errors from your team.
Can I use multiple log sinks after fixing mysql error 4003?
Yes, MySQL allows multiple log writers at the end of the service chain. The rule only warns against running more than one filter component at the same time.
Why did this warning appear right after a server restart?
A startup file or automation script likely loaded a second filter into the global variable. Check all startup files to remove the duplicate filter entry.