How to Fix MySQL Error 1799 (ER_INNODB_ONLINE_LOG_TOO_BIG)
You see mysql error 1799 when an online table change fills the temporary log buffer. You can fix it by raising the log limit or running the change during quiet hours. This failure uses the symbol ER_INNODB_ONLINE_LOG_TOO_BIG and SQLSTATE HY000 in the database engine. The engine stops the index build when concurrent writes exceed the innodb_online_alter_log_max_size byte limit. The table stays intact, and your app keeps running without losing any data. Why mysql error 1799 happens during onlin
Your coding agents run with your access.
Claude Code reaches prod with a developer's credentials, and approval prompts get clicked through. hoop.dev checks every query, masks sensitive data, and holds risky changes for a human.
You see mysql error 1799 when an online table change fills the temporary log buffer. You can fix it by raising the log limit or running the change during quiet hours.
This failure uses the symbol ER_INNODB_ONLINE_LOG_TOO_BIG and SQLSTATE HY000 in the database engine. The engine stops the index build when concurrent writes exceed the innodb_online_alter_log_max_size byte limit. The table stays intact, and your app keeps running without losing any data.
Why mysql error 1799 happens during online schema changes
MySQL lets you add indexes or alter tables without blocking reads and writes. While the database rebuilds the index, apps still insert, update, and delete rows. InnoDB cannot write these new changes straight into the index under construction. Instead, the engine stores every concurrent row change inside a temporary modification log.
Once the index build finishes, InnoDB replays this modification log to catch up. Still, the database caps the maximum size of this log to save disk and memory. The innodb_online_alter_log_max_size setting controls how many bytes this temporary log can hold. If your app writes too much data during the alter job, the log fills up.
When the log hits the ceiling, InnoDB aborts the schema change right away. It throws mysql error 1799 and rolls back the new index build. High write traffic on large tables is the top cause of this failure. Long batch jobs or bulk imports running at the same time also trigger this error. Slow disk storage makes the index build take longer, giving the log more time to overflow.
How to diagnose and fix the log overflow in production
Start by checking how much write traffic hits the target table right now. Look at your database metrics for spikes in row inserts, updates, and deletes. Check if a background worker or batch job is writing to the same table. Stopping heavy batch jobs before you alter a table often prevents the overflow.
If you cannot stop app traffic, schedule the schema change for a low-traffic window. Fewer writes per second mean the modification log grows at a much slower pace. The index build will finish before the log reaches the byte limit.
MySQL Access Governance + End-to-End Encryption: architecture patterns and best practices
Continue reading? Get the full guide.
Free. No spam. Unsubscribe anytime.
You can also raise the innodb_online_alter_log_max_size setting before running the schema change again. This setting is dynamic, so a database admin can change it without a server restart. Raising the limit gives InnoDB more space to buffer concurrent row changes. Make sure the server has enough free memory and disk space before raising this limit. Lower the limit back to its normal value after the index build finishes.
Safe ways to run production schema changes
Never grant broad admin rights to every engineer just to fix a schema error. Adjusting global engine settings requires high privileges that can put the whole server at risk. Instead, use a controlled workflow where an approved admin reviews the change first.
When engineers inspect production tables to check write patterns, protect sensitive columns first. Data masking rewrites emails, phone numbers, card numbers, and national IDs in query results. This lets your team check table activity and fix errors while keeping private records safe.
For very large tables, consider using an external online schema change tool. These tools copy rows in small batches to a shadow table and swap tables at the end. Because they do not use the internal InnoDB modification log, they avoid this error.
Add wire guardrails and masking beside MySQL
Database grants and TLS setup decide who can reach MySQL. Even so, an open session can run broad updates or read raw personal data from allowed tables. In practice, hoop.dev sits inline in the wire protocol beside the database as a sidecar for your MySQL. On every production query an agent or engineer sends, hoop.dev decides to pass, mask, block, or escalate it for human review.
With hoop.dev MySQL support, guardrails refuse bad queries before they run or hold risky calls for approval, while data masking rewrites matched sensitive values in result rows in memory. Furthermore, hoop.dev holds SOC 2 Type II and generates evidence for GDPR, HIPAA, and PCI DSS programs. Read the docs and source on GitHub.
Frequently asked questions
Does mysql error 1799 corrupt my table or lose data?
No, this error does not corrupt your table or lose any app data. InnoDB cancels the index build cleanly and keeps all concurrent row changes intact.
Do I need to restart MySQL to raise innodb_online_alter_log_max_size?
No, you do not need to restart the database server to change this limit. An admin can update this global setting on a live server before retrying the alter job.
Why did the error happen on a small index change?
The log size depends on concurrent writes to the table, not the new index size. If a big table takes twenty minutes to scan, heavy app writes will still fill the log.
Related guides
In this post